8 Dolby
®
Media Meter 2 User’s Manual
Measuring Loudness
Figure34 
Figure 3-4 Stand-Alone Meter Measuring an Encoded File
Tomeasuretheloudnessofanencodedfileorasourcefileset:
1. Clicktochooseeither
Source filesoranEncoded file.
2. Identifytheinputfileorfiles,eitherbybrowsingthenetwork,orbytypingafilename
andlocationintothenamefield.
AsinotherDolbyMediaProducerapplications,thefileselectorisintelligent.When
youdoubleclickasourcefile,DolbyMediaMeter2recognizesandselectstheentire
setwhenthesetfoll
owsthenamingconventionsdescribedinSection 3.6.
3. Click
Enableifyouwanttocreatealogfileofthismeasurement.Reviewthedefault
logfilenameandlocation,andmake anyrequiredmodifications.
Bydefault,theDolbyMediaMeter2nameslogfiles
input file name-LoudnessEstimation.csvandsavesthefileinthedirectorywheretheinput
filesarestored.SeeSection 5.1formoredetailsaboutthelogfunction.
4. Click
Specify Rangetomeasureonlypartoftheselectedfile.